www.simpsonanchors.com


TITEN HD® Heavy Duty Screw Anchor for Concrete & Masonry

Shear Loads in Normal-Weight Concrete, Load Applied Parallel to Edge

 
Shear Load Normal Weight Concrete



Note: Rebar not shown for clarity.
Shear Loads in Normal-Weight Concrete, Load Applied Parallel to Edge
  1. The allowable listed are based on a safety factor of 4.0.
  2. Allowable loads may be increased 33 1/3% for short term loading due to wind or seismic forces when permitted by code.
  3. The minimum concrete thickness is 1 1/2 times the embedment depth.
 