www.simpsonanchors.com


TITEN HD® Heavy Duty Screw Anchor for Concrete & Masonry

Shear Loads in Normal-Weight Concrete:

 
Shear Load Normal Weight Concrete
Shear Loads in Normal-Weight Concrete
  1. The allowable loads listed are based on a safety factor of 4.0.
  2. Allowable loads may be increased 33 1/3% for short term loading due to wind or seismic forces when permitted by code.
  3. Refer to allowable load-adjustment factors for spacing and edge distance.
  4. The minimum concrete thickness is 1 1/2 times the embedment depth.
  5. Tension and Shear loads for the Titen HD anchor may be combined using the elliptical interaction equation (n=5/3). Allowable load may be interpolated for concrete compressive strengths between 2000 psi and 4000 psi.
Printed from