www.simpsonanchors.com


TITEN HD® Heavy Duty Screw Anchor for Concrete & Masonry

Shear Loads in Normal-Weight Concrete:

 
Shear Load Normal Weight Concrete
Shear Loads in Normal-Weight Concrete
  1. The allowable loads listed are based on a safety factor of 4.0.
  2. Allowable loads may be increased 33 1/3% for short term loading due to wind or seismic forces when permitted by code.
  3. Refer to allowable load adjustment factors for spacing and edge distance.
  4. The minimum concrete thickness is 1 1/2 times the embedment depth.
  5. Tension and Shear loads for the Titen HD anchor may be combined using the elliptical interaction equation (n=5/3). Allowable load may be interpolated for concrete compressive strengths between 2000 psi and 4000 psi.
Printed from