www.simpsonanchors.com


TITEN HD® MINI Screw Anchor for Concrete and Masonry

Tension and Shear Loads in Normal-Weight Concrete

Shear Load Normal Weight Concrete
Tension Loads in Normal-Weight Concrete
Titen HD Mini - Tension and Shear Loads in Normal-Weight Concrete
  1. The allowable loads are based on a safety factor of 4.0.
  2. The minimum concrete thickness is 1 1/2 times the embedment depth.
  3. Tension and Shear loads may be combined using the straight line interaction equation (n=1).
 
Shear Load Normal Weight Concrete
Shear Loads in Normal-Weight Concrete
Titen HD Rod Coupler Shear Loads in Normal-Weight Concrete Stemwall Load Applied Parallel to Concrete Edge
  1. The allowable loads are based on a safety factor of 4.0.
  2. The minimum concrete thickness is 1 1/2 times the embedment depth.
  3. Tension and Shear loads may be combined using the straight line interaction equation (n=1).
 
Printed from
© 2008 Simpson Strong-Tie®