www.simpsonanchors.com


PCL & PECL Series Ceiling Clips

Tension and Oblique Loads in Sand-Lightweight Concrete

over Metal Deck

PCLDP

PCLDP


PECLDP

PECLDP


For more information see the Fasteners index.

Tension Load Oblique Load Light Weight Concrete over Metal Deck
Tension and Oblique Loads in Lightweight Concrete over Metal Deck
  1. The fasteners shall not be driven until the concrete has reached the designated compressive strength. Minimum concrete thickness is three times the fastener embedment into the concrete.
  2. The allowable tension and shear values are for the fastener only. Connected members must be investigated separately in accordance with accepted design criteria.
  3. Metal deck must be minimum 20 gauge.
  4. Oblique values are for loads applied toward edge of flute.
  5. The fasteners shall be installed 1 1/2 inches from the edge of flute.
 
Printed from