www.simpsonanchors.com


PHNT Series Fasteners

Tension and Shear Loads in Steel


Tension Load Shear Load Steel

PHNT

PHNT
click on the link above for more information on these fasteners

PHNT Series Fasteners - Tension and Shear Loads
detail A
  1. The entire pointed portion of the fastener must penetrate through the steel to obtain the tabulated value. See Detail A.
  2. The allowable tension and shear values are for the fastener to steel only.
  3. Steel must conform to ASTM A36 specifications, with
    Fy = 36,000 psi, minimum.
 
Printed from
© 2010 Simpson Strong-Tie®