www.simpsonanchors.com


PSLV Threaded Studs

Tension and Shear Loads in Steel

Tension Load Shear Load Steel

PSLV4

PSLV4

PSLV3

PSLV3

For more information see the Fasteners index.

PSLV Series Fasteners - Tension and Shear Loads
  1. The entire pointed portion of the fastener must penetrate through the steel to obtain the tabulated value.
  2. The allowable tension and shear values are for the fastener to steel only. Connected member must be investigated separately in accordance with accepted design criteria.
  3. Steel must conform to ASTM A36 specifications, with
    Fy = 36,000 psi, minimum.
 
Printed from
© 2008 Simpson Strong-Tie®